Cables: For US Series

Cables: For US Series

This is a dedicated connection cable between the motor and the speed controller. Product Line varies depending on the motor output power and power supply voltage specifications.
The maximum extension distance is 4.75 m.

Connection Cable for Single-Phase 100 VAC and Single-Phase 200 VAC Types

Motor Frame Size, Output Power Product Name Length (m)
Connection Cable for Single-Phase 100 VAC and Single-Phase 200 VAC Types
60 mm, 6 W
70 mm, 15 W
80 mm, 25 W
90 mm, 40 W
CC-1 1
CC-2 2
CC-3 3
CC-4 4
90 mm, 60 W
90 mm, 90 W
CC01SS2 1
CC02SS2 2
CC03SS2 3
CC04SS2 4
Note:
These cables are for exclusive use with products that conform to the RoHS Directive. The connector is different from the US Series that are not RoHS Directive-compliant products, and so cannot be connected.

Flexible Connection Cable for Single-Phase 100 VAC and Single-Phase 200 VAC Types

Motor Frame Size, Output Power Product Name Length (m)
Flexible Connection Cable for Single-Phase 100 VAC and Single-Phase 200 VAC Types
60 mm, 6 W
70 mm, 15 W
80 mm, 25 W
90 mm, 40 W
CC-1R 1
CC-2R 2
CC-3R 3
CC-4R 4
90 mm, 60 W
90 mm, 90 W
CC01SS2R 1
CC02SS2R 2
CC03SS2R 3
CC04SS2R 4
Note:
These cables are for exclusive use with products that conform to the RoHS Directive. The connector is different from the US Series that are not RoHS Directive-compliant products, and so cannot be connected.

Connection Cable for Single-Phase 110/115 VAC and Single-Phase 220/230 VAC Types

Motor Frame Size, Output Power Product Name Length (m)
Connection Cable for Single-Phase 110/115 VAC and Single-Phase 220/230 VAC Types
60 mm, 6 W
70 mm, 15 W
80 mm, 25 W
90 mm, 40 W
CC01SU05 1
CC02SU05 2
CC03SU05 3
CC04SU05 4
90 mm, 60 W
90 mm, 90 W
CC01SU07 1
CC02SU07 2
CC03SU07 3
CC04SU07 4
Note:
These cables are for exclusive use with products that conform to the RoHS Directive. The connector is different from the US Series that are not RoHS Directive-compliant products, and so cannot be connected.

Flexible Connection Cable for Single-Phase 110/115 VAC and Single-Phase 220/230 VAC Types

Motor Frame Size, Output Power Product Name Length (m)
Flexible Connection Cable for Single-Phase 110/115 VAC and Single-Phase 220/230 VAC Types
60 mm, 6 W
70 mm, 15 W
80 mm, 25 W
90 mm, 40 W
CC01SU05R 1
CC02SU05R 2
CC03SU05R 3
CC04SU05R 4
90 mm, 60 W
90 mm, 90 W
CC01SU07R 1
CC02SU07R 2
CC03SU07R 3
CC04SU07R 4
Note:
These cables are for exclusive use with products that conform to the RoHS Directive. The connector is different from the US Series that are not RoHS Directive-compliant products, and so cannot be connected.

Cable Note When Wiring Flexible Cable

Do not bend the cable at the connector. Stress applied to the connectors and terminals causes poor contact and disconnection.

How to Fix the Cable

Fix the connector part in 2 places to prevent it from moving.

Fix the connector part in 2 places to prevent it from moving.

Wiring Length and Bending Radius of the Cable

Wiring should be installed at an appropriate length, so that cables are not pulled during movement.
In addition, the bending radius (R) should be 6 times the cable diameter min.

Wiring should be installed at an appropriate length, so that cables are not pulled during movement.

Interference of the Cable

Wire the cables in the cable holder without bringing them into contact with each other. This will add stress to the cable, and cause it to break prematurely. Please check note on cable holders carefully before use.

Cable Kinks

◇Please wire without kinks in the cable. Kinking in a twisted state can cause premature disconnection. After wiring, confirm that there are no kinks in the cable, using the print on the cable surface as a reference.