AC Axial Flow Fans MU Series Standard Type
MU1238A-21B

Fan
Phân loại sản phẩm | Tên sản phẩm | Giá niêm yết | Giá niêm yết | Ngày vận chuyển |
---|---|---|---|---|
Fan | MU1238A-21B | SGD 36 | USD 29 | 3 Working Days |
This is a set of panels, finger guards and screws that are ideal for ventilation and cooling of control cabinets.
Available in 3 types: finger guard cover panel set, slit metal cover panel set, dust and water resistant cover panel set.

Bao gồm
- Fan, Operating Manual
Thông số kỹ thuật
Đặc trưng
Kích thước
Tải dữ liệu
Các thông số kỹ thuật khác
General Specifications
Item | Specifications | |||||
---|---|---|---|---|---|---|
Insulation Resistance | 100 MΩ or more when a 500 VDC megger is applied between the windings and the case after continuous operation under normal ambient temperature and humidity. |
|||||
Dielectric Strength | No abnormality is observed even with an application of 1.5 kV at 50 Hz between the windings and the case for 1 minute after continuous operation at normal ambient temperature and humidity. |
|||||
Temperature Rise | After continuous operation at normal ambient temperature and humidity at maximum air flow, when temperature becomes constant, the measurement value on the outer case using the thermometer method is 30 °C max. |
|||||
Operating Voltage Range | ±10 % (for each voltage) | |||||
Thermal Class | UL/CSA Standards: 105 (A), EN Standards: 120 (E) Non-standards certified, Electrical Appliance and Material Safety Act: 120 (E) MRS30: UL/CSA Standards: 130 (B), EN Standards: 130 (B) |
|||||
Overheat Protection | MU, MS Series, MRE10, MRE12: Impedance protected MR, MRS Series, MRE16, MRE18, MRE20, MRE25: Built-in thermal protector (Automatic return type) Open: 120±5 °C, Reset: 77±15 °C |
|||||
Operating Environment | Listed in a separate box | |||||
Storage Conditions | Listed in a separate box | |||||
Color | MU, MS Series Frame: Unpainted (Aluminum) Blade: Black MR, MRS, MRE Series Frame: Dark Gray Blade: Black |
|||||
Materials | Frame: Aluminum die cast Blade: Polycarbonate (Flammability Classification: V-0) |
Operating Environment, Storage Condition
Series | Operating Environment*1 | Storage Conditions*1*3 | Environmental Standards | ||
---|---|---|---|---|---|
Ambient Temperature*2 | Ambient Humidity | Ambient Temperature*2 | Ambient Humidity | ||
EMR Series | -25~+65 °C | 85 % max. (Non-condensing) |
-25~+70 °C | 85 % max. (Non-condensing) |
- |
MU Series Moisture Proof Type | -30~+60 °C | 95 % max. (Non-condensing)*5 Absolute humidity 36 g/m3 max. |
-40~+70 °C | 95 % max. (Non-condensing) |
Compliant with ETSI Standards*4 |
MU Series Standard Type, MRS Series | 85 % max. (Non-condensing) |
85 % max. (Non-condensing) |
|||
MRE Series (MRE16, MRE18, MRE20, MRE25) | |||||
MRE Series (MRE10, MRE12) | -30~+50 °C | ||||
MRS Series □140 mm-47 mm Thick With Low-Speed Alarm | -20~+60 °C | -20~+70 °C | |||
MRS Series Variable Speed Type | -10~+60 °C | − | − | − | |
MS Series | |||||
MR Series | −10~+50 °C |
- *1
- The operating and storage environment assumes conditions of being free from condensation, freezing, and vibration other than that of the fan, and external force.
- *2
- Cannot be used in a temperature-controlled environment at -10 °C max., such as in a freezer.
- *3
- The value for storage condition applies to short periods such as the period during transport.
- *4
- Operating environment and storage conditions are in compliance with the following environmental standards.
ETSI EN 300 019-2-1 Class 1.3E Storage
ETSI EN 300 019-2-2 Class 2.3 Transportation
ETSI EN 300 019-2-3 Class 3.4 Stationary use - *5
-
Test Name | Environmental Standards | Conditions and Test Content |
---|---|---|
Heat Cycle Test | ETSI EN 300 019-2-1 ETSI EN 300 019-2-2 ETSI EN 300 019-2-3 |
-40~+30 °C 5 cycles Temperature Gradient: 1.0 °C/min Low Temperature (-40 °C) High Temperature (+30 °C) Exposure Time: 3 hours No abnormality after test |
Low Temperature Exposure Test | -45 °C 72 hour exposure No abnormality after test |
- *Environmental Standard ETSI
ETSI, officially known as the European Telecommunications Standards Institute, is a standards organization established to produce standard specifications for telecommunications in Europe.
The ETSI EN 300 019 Series is a standard based on IEC 60721, which defines the environmental conditions for equipment, and specifies specific definitions of environmental conditions and test conditions.
Tiêu chuẩn
Regulations and Standards Materials
Documents about compliance with regulations and standards can be downloaded from the "Data Download" tab on the product details page.
(The types of files available for download vary by product.)
Explanations of the Global Laws, Regulations and Standards can be found here.
Information about our compliance with regulations and standards for each of our product series can be found here.
Hazardous Substances
The product does not contain any substances (10 substances) exceeding the regulation values of the RoHS Directive (2011/65/EU, 2015/863/EU).
Cấu hình hệ thống
Những sản phẩm tương tự
Thermostat for Fan
Products | Features | |
---|---|---|
AM2-XA1![]() |
Features |
Automatically operates and stops fans in response to temperature changes in the equipment.
Note
|
Enclosure Fan Module
Products | Features | |
---|---|---|
Enclosure Fan Module | Features |
This product integrates a fan with accessories (covers, filter media, frames, and finger guards to keep out foreign particles, dust, and water droplets).
|
Cáp và phụ kiện