Cooling Fans

Fan motors

We provide heat solutions for our customers, from ventilation and cooling to condensation prevention.
We offer products that are energy-saving, long-lasting, dust-proof, and waterproof, and contribute to adding value to our customers' equipment.

Cooling Fans
Tổng quan và thông tin liên quan

Overview

Precision equipment and electronic equipment consume power and generate heat at the same time. If the heat generated by this equipment causes the entire machine to overheat, it may cause damage to the electronic equipment or equipment failure. As a result, the impact of overheating is significant, potentially leading to not only the shutdown of the equipment but also the entire production system. Condensation and freezing due to low temperatures can also affect the operation of the equipment.
Proper temperature control using fans is essential to prevent such issues caused by heat and humidity.

Types and Main Application Examples

Axial Flow Fan :  For ventilation and cooling, drying, air flow

A fan that uses wing blades (propellers) to generate wind in the direction of its axis rotation.
Because of its large air flow, it is suitable for ventilation and cooling to cool the entire inside of the equipment.
A wide range of products are available to meet various needs, including alarm functions and long life.

Axial Flow Fan

Cooling Medium and Low Density Mounted Equipment

The large air flow of axial flow fans is suitable for ventilation and cooling inside electronic equipment.

Cooling Medium and Low Density Mounted Equipment

Cooling High-Density Mounted Equipment

When the blowing resistance inside the equipment is large, using a large fan with large air flow and high static pressure will save energy and wiring rather than using multiple small fans for cooling.

Cooling High-Density Mounted Equipment

Click here for a tool to easily calculate the required air flow on the website

Centrifugal Blower :  For spot cooling and duct air flow

Since the exhaust outlet is narrowed to focus air to a specified direction, these centrifugal blowers are used for spot cooling. The static pressure is also high, which makes them a suitable choice when cooling equipment through which air cannot flow easily or for air flow using a duct.

Centrifugal Blower

Air-Blow Cooling and Drying

Centrifugal blowers with high static pressures are suitable for the spray cooling of load following heat treatment.

Air-Blow Cooling and Drying

Cooling With High Static Pressure

The high static pressure of centrifugal blowers makes them suitable for cooling used together with filters that are subject to significant pressure losses.

Cooling With High Static Pressure

Cross Flow Fan :  For uniform and wide air flow

It can send out a wide, uniform air flow.
In addition, the compact rectangular shape and right-angle wind-bending feature of the unit allows for effective use of space, such as installation in a corner of the equipment.
It is suitable for applications such as uniform cooling of circuit boards mounted in equipment, and for air curtains.

Cross Flow Fan

Uniform Cooling and Drying

Cross flow fans are suitable for the air-blow cooling of wide areas.

Uniform Cooling and Drying

Cooling a Narrow, Thin Space

It is suitable for air flow cooling of narrow and elongated space (the corner of the equipment) such as the area where electronic equipment is installed.

Cooling a Narrow, Thin Space

Enclosure Fan Module :  For ventilation and cooling and air flow with protection against water droplets, dust and foreign particles

The enclosure fan module is a product that integrates an axial flow fan and accessories (cover, filter media, frame, finger guard). Optimized cooling for control cabinets.

  • Installation and order is easy with the integrated structure
  • Characteristics are clear and easy to select
  • Degree of protection IP43 and IP55 ratings are available
  • Easy installation on the control cabinet by only machining square holes
Enclosure Fan Module

Ventilation and Cooling Inside Control Cabinet

Suitable for ventilation and cooling inside a control cabinet in an environment where powdery dust is mixed in with the air.

Ventilation and Cooling Inside the Enclosure

Click here for details on enclosure fan module

We also offer a set of panels, finger guards and filters, and screws that can be installed on an axial flow fan (single unit) purchased.

Thermostat :  Automatic Operation and Stopping of Fans and Heaters

Thermostat (Thermostat for fan/Thermostat for heater)

Automatically turns the fan or heater ON and OFF in accordance with the temperature fluctuation inside the equipment.
This helps improve the equipment's "environmental" performance relative to energy savings, noise reduction, etc.

Thermostat (Thermostat for fan/Thermostat for heater)
Automatic Operation and Stop at Setting Temperature

Automatically switches between operation and stop when the temperature inside the equipment reaches the setting temperature of the thermostat.

Automatic Operation and Stop at Setting Temperature
Example) When Using a Thermostat for Fan

Click here for details on thermostat for fan

Click here for details on thermostat for heater

For Those Who Have Not Decided on a Series

View More About the Selection Guide

selection guide

Selection Guide

This selection guide will help you find the product series best suited for your equipment. Select an equipment application example and follow the guidance to select a product series.

View More about the Problem Solving Case Studies

Problem Solving Case Studies

Problem Solving Case Studies

Here is the information on the solutions for your equipment issues. We introduce examples of in-house production of equipment used in actual manufacturing sites, as well as application examples of our recommended products to solve the issues with conventional equipment.