Q.Is there any way to check the generated torque (load torque)?

A.

This can be checked using the load factor.

The load factor indicates the percentage of generated torque (load torque) with the rated torque of the motor at 100 %.
The confirmation method varies depending on the product. Refer to the table below.

Brushless Motors αSTEP AC Servo
Motor
Series BMU BLE2 BXII AZ*1 NX*2
Display Range [%] 40~200 0~300 0~250 1~100 0~300
Display Method Driver Display - -
Support software
MEXE02*3
-
Control Module
OPX-2A (Sold separately)
- - -
*1
Refer to the torque monitor (this is the current torque rate when the maximum holding torque is at 100 %).
*2
In the user manual, etc., it is expressed as detection torque.
*3
Download from the download page.
  • The NX Series can output the detected torque as a voltage from the analog I/O connector (output voltage: ±10 VDC).
    Use this function when monitoring with a programmable controller.

Product Category: Brushless Motor ,αSTEP , Servo Motor
Model and Series: BMU Series , BLE2 Series , BXII Series , AZ Series , NX Series
Description: Usage and Setting method , Functions, Characteristics, Specifications, Dimensions , Technical knowledge, materials and terminology