Brushless Motors BLE2 Series

BLE2D60-C

BLE2D60-C

Control Circuit

Phân loại sản phẩm Tên sản phẩm Giá niêm yết Giá niêm yết Ngày vận chuyển
Control Circuit BLE2D60-C SGD 276 USD 221 11 Working Days
• This product is a brushless motor driver circuit only.

Bao gồm

  • Control Circuit: None

Thông số kỹ thuật

Kích thước

Control Circuit
Control Circuit

Control Circuit

Tải dữ liệu

Các thông số kỹ thuật khác

General Specifications

Item Motor Driver
Insulation Resistance 100 MΩ or more when a 500 VDC megger is applied between the windings and the case after continuous operation under normal ambient temperature and humidity.
 
After continuous operation at normal ambient temperature and humidity, the value measured with a 500 VDC megger between the power supply terminal and the protective earth terminal, and between the power supply terminal and the I/O signal terminal is 100 MΩ min.
 
 
Dielectric Strength No abnormality is observed even with an application of 1.5 kVAC at 50 Hz between the coils and the case for 1 minute after continuous operation at normal ambient temperature and humidity.
 
After continuous operation at normal ambient temperature and humidity, no abnormality is observed even if 50 Hz, 1.5 kVAC is applied between the power supply terminal and the protective earth terminal, and 50 Hz, 1.5 kVAC is applied between the power supply terminal and the I/O signal terminal for 1 minute.
 
 
Temperature Rise After rated continuous operation at normal ambient temperature and humidity,
the temperature rise of the coils measured by the thermocouple method is max. 50°C
(max. 60 °C for 300 W and 400 W),
and the measured value of the temperature rise of the case surface is max. 40°C
(max. 50 °C for 300 W and 400 W)*1.
After continuous operation at normal ambient temperature and humidity, the measurement value of the temperature rise of the heat sink is 50 °C max. using the thermocouple method.
 
Operating Environment*2 Ambient Temperature 0∼+40 °C (Non-freezing) 0~+50°C*3 (Non-freezing)
Ambient Humidity 85 % max. (Non-condensing)
Altitude Up to 1000 m above sea level
Atmosphere No corrosive gases or dust Should not be exposed to oil.
Cannot be used in a radioactive area, magnetic field, vacuum, or other special environments.
Vibration Must not be subjected to continuous vibration or excessive shock.
Conforms to JIS C 60068-2-6, "Sine-wave vibration test Method."
Frequency Range: 10~55 Hz, Half Amplitude: 0.15 mm 
Sweep direction: 3 directions (X, Y, Z) Number of sweeps: 20
Storage Conditions*4 Ambient Temperature -20~+70 °C (Non-freezing)
JH Gearhead, JB Gearhead, JV Gearhead: -10~+60°C (Non-freezing)
-25~+70°C (Non-freezing)
Ambient Humidity 85 % max. (Non-condensing)
Altitude Up to 3000 m above sea level
JH Gearhead, JB Gearhead, JV Gearhead: Up to 1000 m above sea level
Atmosphere No corrosive gases or dust Should not be exposed to water or oil.
Cannot be used in a radioactive area, magnetic field, vacuum, or other special environments.
Thermal Class UL/CSA Standards: 105 (A)
EN Standards: 120 (E)
Degree of Protection *5 Dustproof and Waterproof Specifications (GFV Gearhead): IP67
GFV Gearhead, JH Gearhead, JV Gearhead, Round Shaft: IP66
(Excluding mounting surface of the round shaft type.)
FR Gearhead: IP65
JB Gearhead: IP44
IP20)
*1
Attach round shaft types to a heat sink (Material: aluminum) of one of the following sizes to maintain a motor case surface temperature of 90 °C max.
30 W Type: 115x115 mm, 5 mm thickness, 60 W Type: 135x135 mm, 5 mm thickness
120 W Type: 165x165 mm, 5 mm thickness, 200 W Type: 200x200 mm, 5 mm thickness, 300 W, 400 W Type: 250x250 mm, 6 mm thickness
*2
Install the driver to a location that has the same heat radiation capability as an aluminum metal plate.
Single Mounting 200 x 200 mm, 2 mm thickness
Close Mounting 350x350 mm, 2 mm thickness
*3
For close mounting (200 W, 300 W, and 400 W only) and DIN rail mounting, the temperature range is 0~+40 °C.
*4
The value for storage condition applies to short periods such as the period during transport.
*5
The IP indication that shows the watertight and dust-resistant performance are specified under IEC 60529 and IEC 60034-5.
The degree of protection is when the connection cable is connected. The connector for driver connection is excluded.

Note

  • Do not measure insulation resistance or perform a dielectric strength test the motor and driver are connected.

Tiêu chuẩn

Regulations and Standards Materials

Documents about compliance with regulations and standards can be downloaded from the "Data Download" tab on the product details page.
(The types of files available for download vary by product.)

Explanations of the Global Laws, Regulations and Standards can be found here.

Information about our compliance with safety standards for each of our product models can be found here.

Hazardous Substances

The product does not contain any substances (10 substances) exceeding the regulation values of the RoHS Directive (2011/65/EU, 2015/863/EU).

Cáp và phụ kiện

close
close