AC Axial Flow Fans

MR Series

AC Axial Flow Fans MR Series
  • Large AC Axial Flow Fan
  • Dual-Dlade Type and High-Efficiency Type
  • Includes Low-Speed Alarm
  • AC Input, Frame Size 180 mm

Tính năng |AC Axial Flow Fan MR Series

A Variety of Types of Fans are Available for Different Applications

Dual-Blade Type Fan With High Static Pressure

MRS18_MRW18 air flow - static pressure characteristics comparison

High Efficiency, Flat Type

MR18 air flow - static pressure characteristics

An alarm signal is output when the rotation speed of the fan deteriorates due to ingress of foreign particles, etc. This helps with predictive maintenance of equipment issues, as fans can be ordered and replaced before equipment is damaged by heat. It also allows replacement of only those fans with deteriorating cooling capacity when there are multiple fans installed. It can limit the impact on the equipment to minimum.

Low-speed alarm for early detection of deterioration of air flow capacity

Easy Setup With the Finger Guard Set

Finger guards, mounting screws, and filters are included in the set of accessories necessary to use the fan.
Because these products are sets, there is no need to order individual components, and they can be assembled onto the fan immediately upon arrival.

  • *The sets are sold separately from the fan.

Set Contents

  • Finger Guard Set (1 Guard)*1

    • Steel Finger Guard Set
    • Stainless Steel Finger Guard Set
    Finger Guard Set (1 Guard)
  • Finger Guard Set (2 Guards)

    • Steel Finger Guard Set
    • Stainless Steel Finger Guard Set
    Finger Guard Set (2 Guards)
  • Finger Guard and Filter Set (1 Each)

    • Steel Finger Guard and Filter Set
    Finger Guard and Filter Set (1 Each)

Mounting Example

  • Mounting Example of Finger Guard Set (1 Guard)
    • Finger guards are used outside the control cabinet.

      Outside →
      For Preventing Injury
  • Example Mounting of Finger Guard Set (2 Guards)
    • Finger guards are used on both the inside and outisde of the control cabinet

      Inside →
      For Protection of the Workers
      Outside →
      For Preventing Injury
  • Mounting Example of Finger Guard and Filter Set (1 Each)
    • Finger guards are used on the inside of the control cabinet, and filters are used on the outside

      Inside →
      For Protection of the Workers
      Outside →
      For Protection Against Dust
*1
Finger guard or filter cannot be mounted on the discharge side of the low-speed alarm, contact alarm type. Use in combination with the 1-guard set.

Click here for finger guard set

Product Line

Size Type Power Supply Voltage
[V]
Maximum Air Flow
[m³/min]
Maximum Static Pressure
[Pa]
□180mm - 65 mm thick Non-alarm type

Low-speed alarm, electronic alarm type
 
Single-Phase 100
Single-Phase 200
Three-Phase 200
10.5 167
□180 mm-110 mm thick Low-speed alarm, electronic alarm type
 
Single-Phase 100/110/115
Single-Phase 200/220/230
Three-Phase 200/220/230 VAC
13.0 353
Thu hẹp phạm vi sản phẩm

Thu hẹp phạm vi sản phẩm

Tải xuống

Catalog

View More About F-73_fan_mrs_mr
F-73_fan_mrs_mr

F-73_fan_mrs_mr

AC Axial Flow Fan MRS Series and MR Series

PDF

View More About F-75
F-75

F-75

Finger Guard Set for AC Axial Flow Fan

PDF

Operating Manual

Loại sản phẩm và thông tin liên quan