AC Speed Control Motors US Series
US315-402
Thông số kỹ thuật
Đặc trưng
Các thông số kỹ thuật khác
General Specifications
Item | Motor | Speed Controller | |
---|---|---|---|
Insulation Resistance | 100 MΩ or more when a 500 VDC megger is applied between the windings and the case after continuous operation under normal ambient temperature and humidity. |
After rated operation at normal ambient temperature and humidity, the value measured with a 500 VDC megger between the power supply terminal and FG terminal is min. 100 MΩ. |
|
Dielectric Strength | After continuous rated operation at normal ambient temperature and humidity, no abnormalities were observed even with an application of 1.5 kVAC at 50 Hz or 60 Hz between the coils and the case for 1 minute. |
No abnormality is observed even with an application of 1.5 kVAC at 50 Hz or 60 Hz between the power supply terminal and FG terminal for 1 minute after rated operation at normal ambient temperature and humidity. |
|
Temperature Rise | After no-load rated operation at normal ambient temperature and humidity, the motor surface temperature rise measured by the thermometer method is 55 °C max. (45°C or less for a US560, US590 Type). |
- | |
Overheat Protective Device |
US560, US590 Type with Built-In Thermal Protector (Automatic Reset Type) Open: 120±5℃ Reset: 77±15℃ |
- | |
Operating Environment | Ambient Temperature | 6 W~40 W: -10~+40°C (Non-freezing) 60 W, 90 W: -10~+50°C (Non-freezing) |
0∼+40 °C (Non-freezing) |
Ambient Humidity | 85 % max. (Non-condensing) | ||
Thermal Class | 120(E) | - |
Note
-
Do not perform an insulation resistance measurement or a dielectric strength test while the motor and speed controller are connected.
Tiêu chuẩn
Hazardous Substances
The product does not contain any substances (10 substances) exceeding the regulation values of the RoHS Directive (2011/65/EU, 2015/863/EU).
Cáp và phụ kiện
close

close
close