EC Fans EMU Series
EMU1238-1

Fan
Phân loại sản phẩm | Tên sản phẩm | Giá niêm yết | Giá niêm yết | Ngày vận chuyển |
---|---|---|---|---|
Fan | EMU1238-1 | SGD 79 | USD 63 | 11 Working Days |
Bao gồm
- Fan, Plug Cord for Power Supply (1 m, Product Name : PCA2B), Operating Manual
Thông số kỹ thuật
Đặc trưng

Air Flow - Static Pressure Characteristics
Kích thước

Dimensions (Body)

Panel Cut-Out
Tải dữ liệu
Các thông số kỹ thuật khác
General Specifications
Item | EMU938, EMU1238 | EMU1225 | |
---|---|---|---|
Insulation Resistance | After continuous operation at normal ambient temperature and humidity, the measurement value between the input terminal and the frame is 100 MΩ min. using a 500 VDC megger. |
After continuous operation at normal ambient temperature and humidity, the measurement value between the lead wire and the frame is 100 MΩ min. using a 500 VDC megger. |
|
Dielectric Strength | No abnormality is observed even with an application of 1.5 kVAC at 50 Hz between the input terminal and the frame for 1 minute after continuous operation at normal ambient temperature and humidity. |
No abnormality is observed even with an application of 2.5 kVAC at 50 Hz between the lead wire and the frame for 1 minute after continuous operation at normal ambient temperature and humidity. For the alarm type only, no abnormality is observed even with an application of 1.5 kVAC at 50 Hz between the power-supply lead wire and the alarm lead wire for 1 minute after continuous operation at normal ambient temperature and humidity. |
|
Temperature Rise | After continuous operation at normal ambient temperature and humidity at maximum air flow, when temperature becomes constant, the measurement value of the winding temperature rise using the thermometer method is 30 °C max. |
After continuous operation at normal ambient temperature and humidity at maximum air flow, when temperature becomes constant, the measurement value of the winding temperature rise using the thermometer method is 35 °C max. |
|
Thermal Class | UL/CSA Standards: 105 (A) EN Standards: 120 (E) Electrical Appliance and Material Safety Act: 120 (E) |
UL/CSA Standards: 105 (A) EN Standards: 120 (E) |
|
Overheat Protection | Built-in burnout prevention circuit | ||
Operating Environment∗1 | Ambient Temperature∗2 | -20 to +75 °C | -20 to +70 °C |
Ambient Humidity | 20 to 85 % (Non-condensing) | 20 to 85 % (Non-condensing) | |
Storage Conditions∗1∗3 | Ambient Temperature∗2 | -30 to +75 °C | -30 to +70 °C |
Ambient Humidity | 20 to 85 % (Non-condensing) | 20 to 85 % (Non-condensing) |
∗2 Cannot be used in a temperature-controlled environment at -10 °C max., such as in a freezer.
∗3 The value for storage condition applies to short periods such as the period during transport.
Tiêu chuẩn
Regulations and Standards Materials
Documents about compliance with regulations and standards can be downloaded from the "Data Download" tab on the product details page.
(The types of files available for download vary by product.)
Explanations of the Global Laws, Regulations and Standards can be found here.
Information about our compliance with regulations and standards for each of our product series can be found here.
Hazardous Substances
The product does not contain any substances (10 substances) exceeding the regulation values of the RoHS Directive (2011/65/EU, 2015/863/EU).
Cấu hình hệ thống
Những sản phẩm tương tự
Thermostat for Fan
Products | Features | |
---|---|---|
AM2-XA1![]() |
Features |
Automatically operates and stops fans in response to temperature changes in the equipment.
Note
|